Spending money on a new injector cleaner again? Not necessarily!

****

When you use the injector cleaning machine, do you also encounter problems such as not being able to spray the test fluid, not being able to start the machine, etc.? When these problems occur, have you ever thought of replacing your injector cleaning machine? Please do not worry, AUTOOL ultrasonic injector cleaning machine of the vast majority of failures can be solved through the replacement of small parts, does not require you to spend a lot of money to re-purchase a piece of equipment. If you pay attention to some small details when using the machine, you can even avoid many problems.

Warm tips:

  • About ultrasonic injector cleaner, please add professional injector carbon cleaning fluid for cleaning. Please turn on the ultrasonic function after pouring in ultrasonic injector cleaner to avoid dry burning the device without pouring in the cleaning fluid, which may cause damage to the ultrasonic.
    Cleaning fluid link:
  • http://bit.ly/3ZZ9II9
  • Regarding the test fluid, it is recommended to use alcohol (isopropyl alcohol or ethanol) with a concentration greater than 95% or professional injector test fluid. Please do not use any corrosive nature of the liquid containing the test (especially cleaning fluid); corrosive liquid will lead to corrosion of equipment parts, the pump does not work and other phenomena. In this case, it belongs to human damage and we will not repair it free of charge.
    Test Solution Links:
  • https://www.amazon.com/dp/B07J62C1K5/ref=twister_B0D6VNG5RR?_encoding=UTF8&th=1
  • If the equipment is not used for a long time, it is recommended to recycle the test fluid. Avoid corrosion of equipment parts with carbonized test fluid.
  • Common Problems & Solutions:

  • Trouble 1: Can’t spray the test solution when testing?
  • 1. First, please check whether the test liquid is filled to the specified position, the liquid is not enough will lead to the equipment can not produce normal pressure, add to the normal position after continuously press the pressurized button to see whether the pressure gauge has changed.
    2. If the pressure gauge shows that there is pressure, but the equipment still does not inject oil, you need to check whether the injector pulse line is connected reliably. If the connection is loose, please re-plug and try again to see if the test fluid can be injected.
    3. If there is connected to the nozzle, or not spraying oil, you need to assist the oil pump will be removed to test whether it is normal.
    4. Please open the back cover of the machine to test the voltage of the pump, if it shows no voltage, then please contact us to send you a new pump.

  • Trouble 2: Can’t turn on the computer?
  • 1. Check that the fuse in the electrical outlet is intact. 2.
    2. If it is blown, replace with a new 5A fuse. 3.
    3. If it still does not turn on, verify that the power adapter is supplying power to the other boards.
    4. Test the voltage of the power adapter. 5.
    5. Normal input voltage should be 110V or 220V, and normal output voltage should be 12V. If it is confirmed that the power adapter voltage is abnormal, please contact us to send you a new power adapter.

  • Trouble 3: After a period of use, liquid leakage is found?
  • This is usually because the glass tube sealing gasket of the ultrasonic cleaner is worn out, please contact us to send you a replacement and replace it with a new one.

  • Trouble 4: The control panel is broken when you receive the goods?
  • 1. please turn the device on and check if the buttons can operate normally, if they can operate normally, please contact us to reissue a new control panel sticker for you.
    2. If the buttons can not operate normally, please contact us to send you a new control panel.
    3. Please note! The control panel of CT200 ultrasonic cleaner is divided into new and old models, if you need to reissue, we only have the new version of the control panel in our warehouse at present, and the ultrasonic cleaning function can’t be used after replacing it.

  • Trouble 5: The ultrasonic injector cleaner machine doesn’t drain the glass tube during the test and sometimes it can’t store the liquid for the test?
  • 1. First of all, please check whether the oil drain switch is in the correct state, for example, whether it has been twisted or not reset.
    2. After confirming that the oil drain switch is correct, please check whether there is any strong corrosive test liquid added, especially whether the cleaning agent has been added. This is because corrosive liquids can cause changes in the internal piping seals.
    3. If you add corrosive liquids, you need to dismantle the cover plate under the glass tube to see if the gasket inside is deformed or swollen.
    4. If there are problems need to be replaced.

  • Trouble 6: ultrasonic injector cleaner machine does not work when turned on?
  • 1. If you stop working after using it for a period of time, this situation is normal. Our products are with high temperature protection, when the monitoring temperature reaches 70 degrees above will trigger the self-protection mechanism to stop working, need to cool down and then run the work. 2.
    2. but if it doesn’t work when you use it for the first time, you need to check the wiring of the ultrasonic motherboard to see if there is any detachment or looseness, if the wiring is loosened, please re-plug it and try to run again. 3. if it still doesn’t work after unplugging it, it is normal.
    3. If it still can’t be cleaned after unplugging, then please contact us to send you a new ultrasonic motherboard.

  • Trouble 7: Inconsistent CT500 fuel injection?
  • The following two situations exist:
    Situation 1: If different glass tubes show a difference of 2mm after testing, then this is within the normal error range and the injector is normal.
    Scenario 2: The difference between the test results is large, you need to eliminate the problem step by step.
    1. first determine whether the problem is the injector itself or the pulse line, the main board and the fuel distributor. 2. confirm which glass tube injector is the problem, and the difference is 2mm.
    2. Confirm which glass tube has abnormal injection volume, for example, in this case, the No. 4 and No. 6 glass tube flow is abnormal, the other is normal. Select the normal glass tubes #1 and #2 as a control to confirm the problem. 3.
    3. There are two possibilities:
    Possibility 1: Swap No. 1 and No. 2 injectors to No. 4 and No. 6 position for testing, if the measurement result is still a small amount of No. 4 and No. 6 glass tube oil injection, this may be the case that the pulse line and the control motherboard problems, or the oil distributor has an abnormality, resulting in abnormal output. If the measurement result becomes No.1 and No.2 with less oil injection, then it is caused by the problem of the injector itself.
    Possibility 2: Swap the No.1 and No.2 pulse line to No.4 and No.6 position for testing, if it becomes No.1 and No.2 spray volume becomes less, it is the pulse line and the main board problem, if it is still No.4-6 position spray volume is less, it is the problem of the fuel distributor.
    Above accessories failure can contact us for replacement.

  • Trouble 8: CT500 will not fit BMW N54 fuel injectors?
  • 1. You need to wrap the raw tape on top of the injector nozzle.
    2. Select the connector for the set to be 15mm.

    Frequently Asked Questions & Answers:

  • Q1:Does AUTOOL injector cleaning machine support diesel injector?
    A: AUTOOL injector cleaning machine does not support diesel injector detection, but it can be used as a diesel injector cleaner machine, its ultrasonic function can support diesel injector cleaning.
  • Q2: Do AUTOOL CT200 and AUTOOL CT150 support GDI injectors?
    A: These two products do not support GDI injector testing, if you have purchased CT200 or CT150, it is recommended to pair it with a CT60 in order to support the realization of GDI function. At present, we only have AUTOOL CT400 CT500 to support GDI cleaning and testing.
  • Q3: Is it possible to test only one injector port and turn off the others?
    A: It is possible to do so, we are equipped with plugs, so you can plug the other fuel distributor ports when you need to test 1.
  • Q4:What motorcycle injectors can AUTOOL injector cleaning machine support? (such as Yamaha etc.)
    A: Our injector cleaning machine is to support all brands of motorcycle and motorboat injectors. And equipped with motorcycle injector adapter, both cleaning and testing can be supported.
  • Q5: Does it support reverse flushing?
    A: All CT series can support reverse flushing, you can just install it in reverse for flushing directly.
  • Q6: What is the maximum speed that can be reached during the test?
    A: The maximum speed of AUTOOL’s injector cleaning machine can be set to 9999 7500 rpm. It can simulate the real-time state of the injector nozzle in the process of low speed, medium speed and high speed of the automobile engine.
  • The AUTOOL ultrasonic injector cleaner machine is a very cost-effective machine and AUTOOL is able to offer its customers a three-year warranty. This means that during the three years we will send you free replacement parts or a new machine. Even after the warranty period, we can always provide you with after-sales guidance, so if you have any questions, please feel free to contact our after-sales team!

    Online support

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Select your currency
    EUREuro

    Unique promotions and bonuses make 1Win even more attractive for all betting enthusiasts.

    Kasyno online Mostbet oferuje szeroki wybor automatow do gier oraz klasycznych gier stolowych, takich jak ruletka czy blackjack.

    Glory Casino collaborates with renowned software providers for high-quality gaming.

    1xbet supports a variety of payment methods, including cryptocurrency.

    Aviator-am?rc etm?k ucun ?n yaxs? vaxt? tap?n.